User guide
Rev 3.0C Apr.08 63
11
11: 1x/EV-DO Group
Thisgroupincludescommandsspecificto1xandEV‐DO.If
youarenotconnectingtoamodemwhichusesEV‐DOor1x,
youwillnotseethisgroupinthemenu.
Figure 11-1: AceManager : 1x/EV-DO
+CTA=n
Inactivitytimer,inseconds.Typicalnetworksettingscausea
linktogodormantafter10to20secondsofinactivity,no
packetstransmittedorreceived.Thistimecanbeshortenedto
releasethephysicalRFlinksoonerwhentheapplicationonly
transmitsshortbursts.
• n=0:Allowsthecellularnetworktodeterminethe
inactivitytimer.
• n=seconds(maximum20seconds)
$QCMIP=n
MobileIP(MIP)Preferences.OnaMobileIPnetwork,adevice
connectstothenetworkusingPPP.Duringthenegotiation
processtheyourmodemisNOTrequiredtopresenta
usernameandpasswordtoauthenticatebecausetheauthenti
‐
cationparametersarestoredinthe modemitself.
• n=0:Disabled,SIPonly
• n=1:MIPpreferred