User guide

Inputs, Relay Outputs, and Power Status
Rev 2.0 Mar.10 45
Analog Inputs
Connect a wiring lead to an analog input (AIN) at 1, 3, 12 or 14, and the nearest
ground at 2 or 13.
Digital Inputs
Connect a wiring lead to a digital input (DIN) at 9, 11, 20, or 22, and the nearest
ground at 8, 10, 19, or 21, as applicable.
Caution:
Never apply voltage to the Digital inputs. The inputs can only be switched open
or closed to ground.
Relay Outputs
Connect the circuit leads to one of the two relay pairs at 6 and 7 or at 17 and 18.
Monitoring and Setting the I/O
You can monitor the status of both the digital and analog inputs using
ACEmanager or AT Commands and also with special reports sent using RAP. In
ACEmanager, select the I/O group.
You can monitor the status of the relays or set them using ACEmanager, I/O
group, or AT Commands.
Getting Immediate Reports Using RAP
You can set up the PinPoint X to report immediately report the state of an input
when it changes by using *PPFLUSHONEVT. You will also need *PPINPUTEVT,
input event reports, enabled and a server configured for your RAP reports. These
settings are in the PinPoint group in ACEmanager.
Power Modes and Information
The PinPoint X can be configured to switch power modes in response to specific
events, such as when the voltage to the modem drops below a configured
threshold or when the DTR changes, in order to conserve a vehicle's battery life.
The stand-by state, low-power mode, will prevent the modem from draining the
battery while allowing the modem to quickly power up to regular operation when it
is needed.
You can configure Low Power mode using ACEmanager.