Module integration testing
When testing your integration design:
Test to your worst case operating environment conditions (temperature and
voltage)
Test using worst case operation (transmitter on 100% duty cycle, maximum
power)
Monitor temperature at all shield locations. Attach thermocouples to the areas
indicated in
Figure 8-4 on page 60 (Transmitter, Baseband 1, Receiver,
Baseband 2).
Note: Make sure that your system design provides sufficient cooling for the module. RF
shield temperature should be kept below 90
°C when integrated to prevent damage to the
module’s components.
(For acceptance, certification, quality, and production (including RF) test
suggestions, see
Testing on page 71.)