Specifications

Power
Rev 6 Mar.13 Proprietary and Confidential - Contents subject to change 51
Module power states
The module has five power states, as described in Ta bl e 6-5.
Table 6-4: Miscellaneous DC power consumption
1
Signal Description
Current
Unit Notes / configuration
Typ Max
VCC
Module OFF leakage
current
490 830 A Full operating temperature range
USB active current 18 25 mA
High speed USB connection, C
L
= 50 pF
on D+ and D- signals
Inrush current 750 3000 mA
Assumes power supply turn on time
> 100µs
Dependent on host power supply
rise time.
GPS signal
connector
Active bias on GPS port
3.3
(100
mA)
V
GPS connector 1 in Figure 5-1 on
page 39.
1. All measurements are preliminary values
Table 6-5: Module power states
State Details
Host is powered
Module is powered
USB interface active
RF enabled
Normal
(Default
state)
Module is active
Default state when VCC is first applied in the absence of W_DISABLE_N control
Module is capable of placing / receiving calls, or establishing data connections on the
wireless network
Current consumption is affected by several factors, including:
Radio band being used
Transmit power
Receive gain settings
Data rate
Number of active Tx time slots
Low power
(‘Airplane
mode’)
Module is active
State is controlled by host interface using software commands:
+CFUN=0 ([1] AT Command Set for User Equipment (UE) (Release 6)
(Doc# 3GPP TS 27.007)
))