DART 200 CDPD Modem User's Guide

DART 200 CDPD Modem User’s Guide E S-Registers
Sierra Wireless, Inc. E-12
Table E-2. Register summary (cont.)
Register Value Default Description
S111 (RO) 0..FF (hex) Current Area/Cell Color code (0xnn
format)
S112 (RO) 0..100 Current Tx BLER in %
S113 (RO) 0..255 Current SIE (Symbols in Error)
S114 (RO) 0 CDPD V1.1 - Current SPI
0..255, 1..255 CDPD V1.0 - XID RSSI threshold
(threshold, time)
-threshold (first parameter) is dB
above -143 dBW
-time (second parameter) in 1/10 sec
is how long RSSI can be below
threshold before a channel hop must
be taken
S115 (RO) 0 CDPD V1.1 - not used
1..100, 1..255 CDPD V1.0 - XID BLER threshold
(threshold in %, time)
-threshold is 100/(first parameter) %
-time (second parameter) in 1/10 sec
is how long BLER can be above
threshold before a channel hop must
be taken
S116 (RO) 0 CDPD V1.1 - not used
1..100, 1..255 CDPD V1.0 - XID SER threshold
(threshold in %, time)
-threshold is 100/(first parameter) %
-time (second parameter) in 1/10 sec
is how long SER can be above
threshold before a channel hop must
be taken
S117 (RO) bitmapped Function (0xnnnn format)
0-3 Reserved
4-7 Reserved
8-11 XID RSSI Rcvd - bit 8 = 1 means
yes (CDPD V1.0 only)
12-15 Reserved
S118 (RO) 0 0 Reserved
S119 (RO) 0 0 Reserved
S120 (RO) 0..FFFF # of RCV discarded acknowledged
class packets (0xnnnn)
S121 (RO) 0..FFFF # of RCV acknowledged class packets
(0xnnnn)
S122 (RO) 0..FFFF # of TX discarded acknowledged class
packets (0xnnnn)
S123 (RO) 0..FFFF # of TX acknowledged class packets
(0xnnnn)
S124 (RO) 0..FFFF MDIS T200 timer value (in 1/10 sec)
(0xnnnn)