DART 200 CDPD Modem User's Guide
DART 200 CDPD Modem User’s Guide E S-Registers
PN1197-00 Revision 1.0 E-11
Table E-2. Register summary (cont.)
Register Value Default Description
S95 (SM) bitmapped 11 Value Function
0 1 Select CDPD version 1.1
MDLP/SNDCP
1 2 Select CDPD version 1.1
RRM
2 4 Reserved
3 8 For SLIP replace multicast
NEI with point-to-point NEI
4 16 Reserved
5 32 Reserved
6 64 Use V1.1 XID overrides from
S-Registers 45-47,75,98,99
7 128 Reserved
S96 (SM) 0..255 0 Reserved
S97 (SM) bitmapped 2 Value Function
0 1 Reserved
1 2 Reserved
2 4 Reserved
3 8 Restrict channel access to LCI
in S-Register 20
4 16 Reserved
5 32 Use CDPD 1.1 chnl acq when
in V1.0 mode
6 64 View channel scan results
when in V1.1 mode
7 128 Reserved
S98 (SM) 0..255 90 CDPD V1.1 channel re-scan interval
XID override (seconds)
S99 (SM) 0..255 8 CDPD V1.1 channel re-scan RSSI delta
XID override (dB)
S100 (RO)
1..1023 RF channel currently being reported
(may not be acquired)
S101 (RO)
0,1 CDPD available flag: 0=not available,
1=available
S102 (RO)
0...-255 Mean RSSI in dBm for channel being
reported. Valid only if CDPD is
available (SReg101 = 1)
S103 (RO)
0..7 Current Transmit power level:
0=highest, 7= lowest
S104 (RO)
0..255 MDBS power product
S105 (RO)
0..100 Current BLER in %
S106 (RO)
0..100 Current SER in %
S107 (RO)
0..65,535 CDPD V1.0 – Current LASI; CDPD
V1.1 - Current WASI
S108 (RO)
0..65.535 Current SPNI
S109 (RO)
0..255 Current CSI
S110 (RO)
0..65,535 Current Cell Number