DART 200 CDPD Modem User's Guide

DART 200 CDPD Modem User’s Guide E S-Registers
Sierra Wireless, Inc. E-8
Table E-2. Register summary (cont.)
Register Value Default Description
S60 (SM)
(cont.)
6 64 Transmit frame logging
7 128 Use power product override
in SReg36
S61 (SM) bitmapped 143 Value Function
0 1 Reserved
1 2 Reserved
2 4 Reserved
3 8 Enable SLIP header
compression
4 16 Reserved
5 32 Reserved
6 64 Reserved
7 128 Reserved
S62 1.. 3 0 Connection Failure - Process Related
(Read-Only)
1 During the connection process
2 During the transmission of a
packet
3 During the reception of a packet
S63 (RO) 24, 67...82 0 Connection Failure - Probable Cause
24 No socket available
67 Address already in use; for UDP
server (in client mode with
backward compatibility specified)
the destination port cannot be the
same as the listening port.
69 Network is down
70 Network is unreachable
71 Network dropped connection on
reset
72 Software caused connection abort
73 Connection reset by peer
75 Socket is already connected
76 Socket is not connected
78 Connection timed out
79 Connection refused; for DART to
DART the Server is not active or
is of the wrong type
81 Host is down
82 Host is unreachable