User guide

WA_DEV_FEX20_UGD_002 Rev 004 March 08, 2011 99
Fastrack Xtend User Guide
Power Consumption
12.8.1. Hardware Configuration
The following hardware configuration includes both the measurement equipment and the Fastrack
Xtend.
12.8.1.1. Equipment
Three devices are used to perform consumption measurement:
A communication tester
A current measuring power supply
A computer, to control the Fastrack Xtend and to save measurement data
Figure 45. Typical Hardware Configuration for Power Consumption Measurement
The communication tester is a CMU 200 from Rhode & Schwartz. This tester offers all required
GSM/GPRS/EGPRS/CDMA/WCDMA network configurations and allows a wide range of network
configurations to be set.
The 66321D power supply is used to supply the Fastrack Xtend, and it could also be used to measure
the total current drain by the device. The current measurement data is read through the GPIB
connection. Rhode & Schwartz NGSM 32/10 is used when measuring with 32V input voltage.
Note that a SIM card must be inserted during all consumption measurements.
The following table lists the recommended equipments to use for the consumption measurement.
Table 80. List of Recommended Equipments
Device
Manufacturer
Part Number
Notes/Description
Communication Tester
Rhode & Schwartz
CMU 200
Quad Band
GSM/DCS/GPRS/EGPRS,
CDMA, WCDMA
Current measuring power
supply
Agilent
66321D
Used for DC-IN