Signals and Indicators
When used (as an emergency reset), it has to be driven by either an open collector or an open drain
output.
Caution: This signal is for emergency resets only.
Table 37. Fastrack Xtend Reset Status
(Serial
Port) Pin #
Signal
I/O
I/O Type
Voltage
Description
14
Reset
I/O
Open drain
1V8
Fastrack Xtend Reset
Table 38. Reset Electrical Characteristics
Parameter
Minimum
Typical
Maximum
Unit
Input Impedance (R)*
100.3
k
Input Impedance (C)
40
nF
* Internal pull-up
Table 39. Reset Operating Conditions
Parameter
Minimum
Typical
Maximum
Unit
~Reset time (Rt)
1
200
µs
~Reset time (Rt)
2
(at power up only)
20
40
100
ms
Cancellation time (Ct)
34
ms
V
H
*
0.57
V
V
IL
0
0.57
V
V
IH
1.33
V
* V
H
= Hysterisis Voltage
1: This reset time is the minimum to be carried out on the ~Reset signal when the power supply is stabilized.
2: This reset time is internally carried out by the embedded module power supply supervisor only when the
embedded module power supplies are powered ON.