16.3.2.2. Environmental Resistance Stress Test
The following tests the Fastrack Xtends resistance to extreme temperature.
Table 94. Environmental Resistance Stress Test
Designation
Condition
Cold Test
COT
Standard: IEC 680068-2-1, Test Ab
Special conditions:
Temperature: -40°C
Rate of temperature change: dT/dt >= ± 3°C/min
Recovery time: 3 hours
Operating conditions: Un-powered
Duration: 72 hours
16.3.2.3. Corrosive Resistance Stress Test
The following tests the Fastrack Xtends resistance to corrosive atmosphere.
Table 95. Corrosive Resistance Stress Test
Designation
Condition
Moist Heat Cyclic Test
MHCT
Standard: IEC 60068-2-30, Test Db
Special conditions:
Upper temperature: +55 ± 2°C
Lower temperature: +25 ± 2°C
RH:
Upper temperature: 93%
Lower temperature: 95%
Number of cycles: 21 (1 cycle/24 hours)
Rate of temperature change: dT/dt >= ± 3°C/min
Recovery time: 3 hours
Operating conditions: Un-powered
Duration: 21 days