AirCard 402 Modem - User Guide
42 2131144
Radio frequency and electrical
specifications
Off No service is available.
See the suggestions for “Amber, blinking” on page 41.
Amber,
blinking
1X coverage is detected. Ready to connect to the network (click
Connect).
Amber, not
blinking
The modem is connected to the 1X network, and can send or receive
data.
Blue,
blinking
1x-EVDO coverage (Rev. 0 or Rev. A) is detected. Ready to connect to
the network (click Connect).
Blue, not
blinking
The modem is connected to the 1x-EVDO network, and can send or
receive data.
Table 6-1: LED operation (continued)
LED State Indicates
Table 6-2: Radio frequency and electrical
specifications
Approvals Compliant with:
IS-2000 Release 1.0 (CDMA 1X)
IS-707-A Data, IS-856 (CDMA 1x-EVDO), IS-866,
IS-878, IS-890, CDMA Development Group
FCC
Industry Canada
Voltage +3.3 Vdc from ExpressCard or PC Card slot
Current Maximum: 1300 A
Typical data call current (talk mode):
350 mA (1X)
430 mA (1xEV-DO)
Standby: 100 mA (1xEV-DO/IS2000 hybrid
mode)
Transmitter
power
200 mW (+23 dBm) average
Transmit PCS: 1850 to 1909.95 MHz
Cellular: 824.04 to 848.97 MHz
Receive PCS: 1930 to 1989.95 MHz
Cellular: 869.04 to 893.97 MHz
GPS: 1575.42 MHz
Channel
spacing
1.25 MHz
Frequency
stability
±150 Hz