User`s guide
Sierra Video Systems
14
The “Control Panel Setup” window sets and reads the control panel settings of the routing
switcher. Under the “Control Panel Number” list, ** denotes panels detected on the
system.
Select the panel ID number for the panel whose status you want to view.
By pressing the “Poll Current Panel” button, G.R.I.P. sends to the routing switcher a
request for panel output and level control status of the currently selected panel.
Outputs that are enabled are displayed in the “Actual Panel Status” window. The Level
“Enable/Disable” buttons show and set the levels a panel will control.
If a box is checked in the “Actual Panel Status” window, this means the selected panel
can control the “Checked” output. To block or un-block an output, click on the box next
the output(s) listed in the Selected Outputs window.
“Remove All” removes all check marks from the Selected Outputs window.
“Add All” adds checks destinations in the Selected Outputs window.