6
Configuration Mode
To enter the configuration mode from normal mode (with the red Lock LED off) hold the
Lock button down for about 3 seconds. The configuration or ‘menu’ mode will be entered,
an on-screen menu will appear and the red Lock LED will illuminate. If the Lock button is
depressed again, any changed settings will be saved and the unit will return to normal.
The currently loaded firmware version will be indicated at the top of the on-screen menu.
The main ‘menu’ mode controls are as follows:
Function keys (up/down arrows) scroll the menu cursor up and down to select the
desired function.
Select Parameter keys (left/right arrows) select settings to apply to the chosen
parameter.
Lock button exits 'menu' mode and saves settings.
SYSTEM CONFIGURATION PARAMETERS
Network Settings Set manually (using settings below) / Use DHCP
IP Address Enter frame IP address byte at a time in the sub-menu
Netmask Enter Subnet Mask byte at a time in the sub-menu
Gateway If required, enter the Gateway address byte at a time in the sub-
menu
DNS Server 1 If required, enter the DNS server address byte at a time in the sub-
menu
DNS Server 2 If required, enter the DNS server address byte at a time in the sub-
menu
Network Settings
These settings only need to be manually entered if DHCP is not to be used. This would
be required for a network that uses fixed IP addresses and does not rely on a DHCP
server to allocate them automatically.
The IP address must be unique on the network. Please see your system administrator if
these details are required.
Keyboard Operation
Any HID compliant USB keyboard can be used for the entry and editing of UMDs. The
keyboard is connected to the USB port on the front panel of the SM-xx, or alternatively,
the SV-Remote remote control unit. Note that a keyboard connected to a remote control
unit that has been assigned to more than one multi-viewer at a time (‘collective mode’)
can serve no function (see the Remote Panel section).
The Tab key activates the cursor on the topmost UMD. Successive Tab key operation
moves the cursor on to the next UMD in sequence. The Esc key deactivates the cursor.
All multi-viewer factory default settings (including the IP address) are restored with the
Ctrl-Alt-Del command.