Instruction manual

Instruction Manual Smart-Trak
®
50 Series
IM-50 Rev. A.2 37
For measuring or controlling flows below 5 sccm, please consider Micro -Trak
TM
Model 101. Above
50 slpm, please consider the Smart -Trak
®
Model 100 Series
Gas Pressure:
145 psig (10 barg) maximum, burst tested to 225 psig (15 barg)
Differential Pressure Requirement 1 to 20 psid (0.07 to 1.38 bard), flow range dependent
Gas and Ambient Temperature 32
°
F to 122
°
F (0
°
C to 50
°
C)
Leak Integrity
5 X 10
-5
atm cc/sec of helium maximum
Power Requirements
Meter: 15 or 24 VDC (+/- 10%) 85 mA regulated Controller: 24 VDC (+/-
10%), 315 mA, regulated RS-485 option adds 130 mA
Control Range
5 to 100% of full scale flow (20:1) at published accuracy. Automatic shut-off off at 4.9% of full
scale
Output and Command (Setpoint) Signal
RS-232 (standard)
Linear 4 - 20 mA or 0 - 5 VDC optional, 500 ohms maximum load resistance.
RS-485 optional (no analog outputs)
Zero, span, and setpoint are field adjustable via supplied user software and RS-232
communications cable
Display
Flow rate, units, full scale, and setpoint. Display may be mounted on the front or back of the unit
Pressure Drop (1/4” standard fittings)
Flow
Range
Flow Rate Meter Controller
slpm
Minimum Delta P psi
(mbar)
Minimum Delta P psi (mbar)
1
0.02
0.45 (31.0)
1.0 (69.0)
2
0.2
0.45 (31.0)
1.5 (103..4)
3 1.0
0.50 (34.5)
2 (137.9)
4 5 0.60 (41.4)
4 (275.8)
5 10 0.80 (55.2)
7.5 (517.1)
6
20
1.2 (82.7)
12.5 (861.8)
7 50
3.0 (206.8) 15 (1034.2)