Connecting To Video Devices
Video sources and output devices (such as monitors, or recorders) may be connected to the
routing switchers through the BNC type connectors located on the back of the unit. Keep in mind
that the output signal format will be that of the input signal format.
Input Equalization
The 1602 Series HD/SDI routers have adjustable input equalization settings. The factory default
setting for Equalization is ON.
There are two states for the equalization setting - active (ON) or bypassed (OFF).
To adjust input equalization via the front panel;
Hold down the "V" level button to trigger adjustment mode. When active, the LED's for all sources
will update to display the current state of their associated adjustment.
Pressing any input button will toggle the state of that button's adjustment.
LED ON indicates the equalizer is on.
LED BLINKING indicates equalizer is off.
Releasing the "V" level button will terminate adjustment mode.
Note:
Output buttons will also light, indicating the Reclocking status. (See next section).
Reclocking
The 1602 Series HD/SDI routers also have adjustable output Reclocking settings. The factory
default setting for Reclocking is ON (automatic).
The Reclocking circuit, when in the automatic mode, will automatically detect and lock to
incoming SMPTE SDI data signals.
If a non-SMPTE data rate is detected, the reclocker will automatically enter the bypass mode in
order to pass the signal without reclocking.
There are two states for the Reclocking setting - automatic (ON) or bypassed (OFF).
To make adjustments, hold down the "V" button to trigger adjustment mode. Pressing any output
button will toggle the state of that button's adjustment.
LED ON indicates the Reclocking circuit is in the automatic mode.
LED BLINKING indicates Reclocking circuit is bypassed.
Releasing the "V" level button will terminate adjustment mode.
Note:
Input buttons will also light, indicating the equalizer status. (See previous section).