SIERA ELECTRONICS SOUND & SECURITY IP CAMERA INSTRUCTION MANUAL VSP 3001 IP CAMERA www.sieraelectronics.
PREFACE Warning: Please read this manual carefully before using.
CONTENTS 1 Introduction 2 1.1 technology support 1.2 system requirements 2 Panel description 3 2.1 front view 2.2 rear view 3 Installation 4 3.1 cautions 3.2 step 4 Illustration for net connection 5 4.1 onnect with PC directly by category 5 cable 4.2 connect to INTRANET through HUB/Switch 4.3 connect to INTERNET through HUB/Switch/Router 5 IP camera pages 7 5.1 home page 5.3 setup page 5.5 time 5.7 general user 5.9 multi-camera screen 5.11 transfer image in the timer mode 5.
1 INTRODUCTION 1.1 Features Built-in web server, high quality JPEG image can be displayed through Internet browser upon connection with Ethernet. Motion JPEG can be up to 15 frames per second with high resolution 640x480. Through Internet, pan/tilt heads and lens can be conveniently controlled to meet with long-range monitoring. Based on ASP/JAVA script, web server can provide max. platform compatibility.
2 PANEL DESCRIPTION 2.1 Front view Power indicator Lens 2.
3 INSTALLATION 3.1 Cautions Please read all safety instructions carefully before installation. VSP-3001 IP camera should installed indoors generally. The prolonged exposure under the sunlight or other strong lights shall accelerate the aging of the shell and shorten the using term. Please install the IP camera at safe site. The fall may cause the damage. Do not place the network camera near water and assure the IP camera in a dry circumstance with aeration.
4 ILLUSTRATION FOR NET CONNECTION He common connection programs for VSP-3001 network camera: 4.1 Connecting directly to PC(through category 5 cross cable) Cross reticle Users For this program, the page browsing requires the basic configuration as below for PC and IP camera: A Connect correctly with the IP camera as above illustration. B Set up the Ethernet card of the PC as auto or 10M half duplex mode. C Set up the static IP address and the subnet masks. For example, IP address is 192.168.1.
4.3 Connecting to Internet through HUB/Switch/Router INTERNET Users Link Builder / Switcher Router Users Reticle Record server For this program, not only the basic setup of PC and IP camera but also the setup of Port Forwarding function of Router is required, so the visit for network camera besides Intranet is accessible. The Router should have the function of Network Address Transition(NAT) to transit the global address to local address and assign the different external port No. to each IP camera. 4.
5 IP CAMERA PAGES 5.1 Home page There are 3 options on home page: 1) image browsing (single camera screen/multi camera screen) 2) configuration 3) help 5.2 Video page Click single camera screen mode, following dialogue box appears: In put network password Please input users and password Webserver: 192. 168. 0.
Enter user name and password of administrator and general user, then following dialogue box appears: click left operation bars to adjust the image directly: Brightness 17 levels Resolution 640 480 Quality favor clarity Image size x1 320 240 standard 160 120 favor motion x2 5.3 Setup page Click system configuration, following dialogue box will appear if the setup of administrator or general user has been made: In put network password Please input users and password Webserver: 192. 168. 0.
Enter user name and password of administrator, then setup page appears.
5.4 Network Name of network camera 4-15 English characters and 2-7 Chinese characters Port no The range is 1-65535(default:80). If there are 2 or more network cameras in 1 LAN and connect to Internet or other net through router, it will be possible to set different port no. for each network camera. Assign IP address Enter IP address and submit mask assigned by administrator to every data field.
5.5 Time item 1.current date and time description settings Display current date and time of IP camera. 2.set up date and time Adjust internal clock (1) have the same time with PC Take the internal clock of network camera with the same time of the PC. (2) input by handwork Input time by handwork to adjust the internal clock of network camera. 11 yyyy-mm-dd for year 1970 to 2039. hh:mm:ss for 24h mode.
5.6 Administrator [Authentication] [None]: anyone can access all pages. [administrator only]:for setup page [administrator]for setup page and [general user] for viewer page [user name and password]:user name should be 4-15 English words or 2-7 Chinese characters. Password should be 4-15 English words or numbers. User name and password should not be blank, [”], ['], [#], [&], [%], [=], [+], [ ], [<], [>], [ ]. 5.7 General user [general user information]: list all user name of general users.
5.8 Image settings [brightness adjust]:17 levels, control the function for brightness adjustment. [Header display]: display the name of network camera and time on image or not. [Power line frequency]: 50HZ and 60HZ optional. Select correct power frequency and prevent fluorescent light interfering the image. [Power indicator]: indicate the network camera is power on or not. [Image size]:100 levels for optional. It means the ratio between images before and after compression.
5.10 Alarm trigger The alarm mode means the transmission of pre and/or post alarm images held in the buffer to specified address. Alarm: select enable to confirm the alarm mode function. [Alarm occur condition]: the alarm is subject to the rising or falling of voltage detected by the I/O connector. rising: the alarm is subject to the rising of voltage detected by the I/O connector. Falling: the alarm is subject to the falling of voltage detected by the I/O connector.
[Image setting]: select the parameters for the image which shall be transferred. Image resolution: 640 480 / 320 240 / 160 120. Image quality: favor clarity / standard / favor motion [Image buffer setting]: the images held in the buffer pre and/or post alarm in short-term. Select the image buffer frequency and the number of images which shall be transferred into the buffer pre and/or post alarm. [Transfer method]: select FTP or E-mail.
5.11 Transfer image in the timer mode Timer mode means sending images to specified address when the clock reaches the pre-assigned time. [Timer]: select the function of transferring image in the timer mode or not. [Timer setting]: 8 timers is optional. [Image setting]: select the parameters of images which shall be sent when it reaches the pre-assigned time. Resolution: 640 480 / 320 240 / 160 120. Image quality: favor clarity / standard / favor motion.
5.12 Background recording function Background recording means sending images to background FTP server for recording at specified intervals. [Record]: select the background recording function or not. [Image setting]: select the parameters of the image recorded in background. Resolution: 640 480 / 320 240 / 160 120. Image quality: favor clarity/stand/ favor motion [image buffer frequency setting]: select the frequency for sending images for recording. [FTP server]: refer to section 4.3.7-alarm trigger-FTP.
6 RECORDING FUNCTION 6.1 Activex control recording ActiveX control recording function is for IE browser only, and can not for Netscape Navigator browser. Please right-click the mouse at the image and select the recording setting in the option box appeared when browsing. [File path]: select the folder in which JPEG files saved. [File name]: enter the file mark. Actual recorder file is name(file+date+time) [interval] 6.2 FTP recording The FTP server is demanded.
7 I/O DESCRIPTION 7.1 About I/O The I/O connector controls input and output of signal, and it includes 1 I/O input terminal, 1 I/O output terminal and 1 RS-232 converter or half duplex RS-485 port. Port description: Port 1 2 3 4 5 6 7 8 Name AGND 485B/RXD 485A/TXD DGND +12V I/O-OUT I/O-IN hold Description analog ground digital ground max.
8 APPENDIX Appendix 1: Reset to factory default In some case, we need reset the server to factory default which can operate on Setup Page. If the user can not login the Setup Page(such as forgetting the user name and the password), it will be available for resetting to factory default through ARP and PING to re-assign the IP address. Notes: after the success of re-assigning the IP address through ARP and PING, all other settings shall be reset to factory default except IP address setting.
2 3 4 5 6 7 8 clear ARP: enter. Set up ARP: enter. PING: enter. Turn off the network camera. Turn on the network camera again. Enter Ctrl-c after Pinging, and enter to clear ARP statistics. Enter to quit the DOS. Display as below: C:\>arp -d C:\>arp -s 192.168.1.61 00-0c-e8-00-00-01 C:\>ping -t 192.168.1.61 Pinging 192.168.1.61 with 32 bytes of data: Request timed out. Request timed out. Request timed out. Reply from 192.
Appendix 2: Troubleshooting Problem Cause the problem of Ethernet connection Remedy Please check the VSP-3001 network camera, the Hub, the Switch and Ethernet indicator. Check their connection if there is any abnormity. conflict of IP Disconnect the Ethernet connection, perform PING. The success of PING shows a conflict for IP address, so re-assign address the IP address of VSP-3001 network camera is needed.
Appendix 3: Specification Hardware I mage Image size CPU: 32 Bits RISC ROM: 2M Bytes Flash ROM RAM: 16M Bytes SDRAM 1 RJ-45 for Ethernet 1 I/O input terminal and 1 I/O output terminal 100 levels are optional Brightness Resolution NTSC/PAL: 640x480, 320x240, 160x120 Ethernet port Ethernet(10 Base-T) Network protocol Performance TCP/UDP/IP, ARP, ICMP, HTTP, TFTP, Telnet, SMTP Trigger and response max. 30 frames/second. Net: max.