Instruction manual

LS300G GSM/GPRS/EDGE/HSPA+ Sierra Wireless Cellular Modem
2 SMA antenna connectors (primary, GPS/diversity)
Active antenna support
Power
Input Voltage: 7 to 28 Vdc
Current Consumption (@12 Vdc)
o Dormant (idle for 10 to 20 s): 185 mA
o Transmit/Receive: 255 mA
Frequency
GSM/GPRS/EDGE: 1900/850/900/1800 MHz
HSPA+[WCDMA]: 1900/2100/850 MHz
If WCDMA operation at 900/1200 MHz is required, an alternate radio
module (SL8092) is available.
Size
Dimensions: 76 mm x 90 mm x 25 mm (3.0 in x 3.5 in x 1.0 in)
Weight: 190 g (6.7 oz)
Environmental
Operating Temperature Range: 30 to 70 °C (22 to 158 °F)
Storage Temperature: 40 to 85 °C (40 to 185 °F)
Humidity: 90% @ 60 °C
Military Specification : MIL-STD-810 conformance to thermal,
mechanical shock, and humidity
Industry Certifications
PRCRN, R&TTE, FCC, Industry Canada, CE, RoHS Compliant,
Class 1 Div 2
7. Installation
7.1 Base Station Requirements for LS300G
PC running Campbell Scientific’s LoggerNet or PC400 software with access to
the Internet.
7.2 Datalogger Site Equipment
LS300G modem with power cable (included with modem).
Datalogger21X, CR510, CR10(X), CR23X, CR7, CR2XX, CR1000,
CR5000, CR3000, CR800 Series, CR6 Series.
9