Specifications
XT65/XT75 Hardware Interface Description
3.3 Power-Up / Power-Down Scenarios
s
XT65_XT75_HD_v01.001 Page 31 of 133 2007-1-8
Confidential / Released
which shall be altered to AT\Q3 (RTS/CTS handshake). If the application design does not integrate RTS/CTS
lines the host application shall wait at least for the "^SYSSTART" or "^SYSSTART AIRPLANE MODE" URC.
However, if the URCs are neither used (due to autobauding) then the only way of checking the module’s ready
state is polling. To do so, try to send characters (e.g. “at”) until the module is responding.
See also Section 3.3.2 Signal States after Startup
Figure 5: Power-on with operating voltage at BATT+ applied before activating IGT
For details on how to use EMERG_RST to reset applications
or external devices see Section 3.3.1.6.