Dynamic battery life calculation
NOTICE
Change battery
Erroneous calculation of battery life
The number of batteries must be configured using the service software when replacing
batteries. This ensures that the meters can correctly calculate battery life.
The date (month, year) the batteries are replaced can also be read out remotely via the
M-bus wire or M-bus RF.
Dynamic battery life calculates the probable remaining battery life.
The calculation is based on meter consumption and configuration. Any change to the
configuration is automatically applied to battery life. If the meter determines energy use is
higher or lower than expected, it lowers or increases its battery life.
Important:
Replace ALL batteries at the same time for an accurate calculation.
Communication
Meters are equipped with an optical interface and two water meter pulse inputs as standard.
You can use one of the following communication modules to remotely read out data:
Pulse output module
M-bus module
RF module
The modules do not impact the acquisition of consumption data. You can upgrade the
modules at any time without violating the security seal.
Communication module
The communication modules are connected to a reaction-free plug that can be installed or
updated at any time.
Compliance with ESD regulations must be ensured.