User Manual
4 Error messages
The meter constantly performs a self-diagnosis and can
recognise and display various metre and installation errors.
If the error message F0 is displayed, flow measurement is
not possible, e.g. due to air in the volume measuring
section.
The error messages F1, F2 and F5, F6, F8 indicate that the
temperature sensors are defective.
If the error message F4 is displayed, the battery is empty.
The error messages F3, F7, F7F and F9 indicate that the
electronics are defective.
In all cases, notify the Service Department.
5 Technical data
General
Note
Please note the information on the meter!
Measuring accuracy Class 2 or 3 (EN 1434)
Mechanical class M2 (2014/32/EU)
Electromagnetic class E1 (2014/32/EU)
Ambient humidity < 93% rel. humidity at 25 °C, non-
condensing
Max. altitude 2000 m above sea level
Storage temperature -20 … 60 °C
Calculator
Ambient temperature 5 … 55 °C
Housing protection class IP 54/IP 68 optional (EN
60529)
Response limit for ΔT < 0.2 K
Temperature difference ΔT 3 K … 120 K
Temperature
measurement range
0 … 180 °C
LCD 8-digit
Optical interface Standard (EN 62056-21)
Communication Optional, e.g. M-bus
Splitability Always removable, cable
length optional
Temperature sensor
Type
Pt500 or Pt100 (EN 60751)
Temperature
range
0 ... 150°C (up to 45 mm overall
length)
0 ... 180°C (from 100 mm overall
length)
Volume measurement unit
Protection class IP 54/IP 65/IP 68 optional (EN
60529)
Installation location Warm side/cold side;
parameterisable
Installation position any
Measuring range 1:100
Temperature range 5 … 130 °C
National approvals may differ.
recommended for...
... heating applications 10 … 130 °C
... cooling applications 5 … 50°C
Maximum overload 2.8 x qp
Nominal pressure PN16 (PS16), PN25 (PS25)
Power supply
Type of power supply Battery for 6 - 20 years
Battery type AA cell lithium
Lithium content 0.65 g per battery
Number of batteries 1 - 4, depending on configuration
Note
The documentation provided with our products
(devices, applications, tools, etc.) or purchased in
parallel must be read carefully and completely before
using the products. We assume that the users of the
products and documents have been authorised and
trained accordingly and also possess the necessary
expertise to be able to use the products correctly.
Further information about the products and
applications is available:
• At your nearest Siemens branch
http://
www.siemens.com/bt/download or system
supplier.
Please note that Siemens shall not be liable for any
damages resulting from failure to observe or
improperly observing the above points to the extent
permitted by law.
Siemens Smart Infrastructure A6V11906002 14.01.2020 11