Data Sheet for Product
8
Smart Infrastructure
CE2N5372en
2021-12-
07
General / Communication
LOOP 3
1234567 Device number, 7 digits
OMS RF standard (M-bus RF only)
Unbind Meter not connected (M-bus RF only)
Bind Meter connected (M-bus RF only)
MbuS Interface (only for M-bus)
127A Primary address (only for M-bus)
0000000A Secondary address (only for M-bus)
01.01 Due date (yearly set day)
01.--.-- Monthly value (monthly set day)
I 5-00 FW Firmware version
CrC 1234 CRC code, part requiring calibration
Other
LOOP 4
17.11.11 Current date [DD.MM.YY]
10.38.57 Current time of day [hh.mm.ss]
------- C Code entry for test/parameter operation
Error codes
The meter continuously performs self-diagnostics, allowing it to detect and display a number
of mounting or device errors.
FL nEG Wrong direction of flow
DIFF nEG Negative temperature differential
F0 Flow cannot be measured
F1 Break in sensor heat side
F2 Break in sensor cold side
F3
Electronics for temperature assessment
defective
F4 Battery empty, power supply problem
F5 Short circuit sensor, heat side
F6 Short circuit sensor, cold side