Remote sensor
Heat cost allocators with a remote sensor are not directly installed at the radiator. The parameter
“Remote sensor” influences the Kc value of the radiators to be equipped.
The selection of the remote sensor can determine whether the heat cost allocator is installed via the
remote sensor or not.
Installation height
The options “75%”, “50%” and “deviating” are available as the installation heights.
The parameter “Installation height” influences the Kc value of the radiators to be equipped. The
radiators in the table will be updated after the selection.
Deviating installation height
The fields “Construction height of the radiator” and “Height of the reference point” will be activated
when selecting a deviating installation height. The installation height will be calculated by entering the
construction height of the radiator and the height of the reference point. It is important that the
deviating installation height must be between 66% and 75%.