Product manual

Advanced Server Registry Advanced Server Key Descriptions
Product Manual U7613-J-Z815-6-76
© Siemens Nixdorf Informationssysteme AG 1995 Pfad: D:\O7613e6\u7613e.k13
The following table describes the meaning of the default value:
13.5.6 RPC Parameters Entries
The Registry path that contains entries for the Advanced Server RPC Parameters is as
follows:
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services
\AdvancedServer\RpcParameters
BrowserMaxCalls REG_DWORD 5 - infinity
The maximum number of open browser sessions that an lmx.srv process can support
simultaneously.
Default: 20
EventlogMaxCalls REG_DWORD 5 - infinity
The maximum number of open event log sessions that an lmx.srv process can support
simultaneously.
Default: 20
Client Range Minimum sessions per lmx.srv Maximum sessions per lmx.srv
1-19 2 12
20-34 2 20
35-49 2 24
50-84 3 28
85-99 4 28
100-129 5 32
130-179 6 36
180-249 8 42
250-349 9 44
350-499 10 50
500-749 10 60
750-999 10 80
1000+ 10 101