Advanced Server Overview and Installation

Introduction to Advanced Server for UNIX Compatibility
Product Manual U7613-J-Z815-6-76
© Siemens Nixdorf Informationssysteme AG 1995 Pfad: D:\O7613e6\u7613e.k02
2.7.4 LAN Manager/X V1.1
Version 2.0 and later of LAN Manager/X or Advanced Server for UNIX are compatible with
Version 1.1 as regards the following:
The environment variable $xLMX
The environment variable $LM_HOMEDIR
The file /etc/rclmx, in which the environment variables are set
The automatic call of /etc/rclmx from the script /etc/profile
The utilities
d
os2unix and unix2dos, which can be called under the system path and
under $xLMX/bin
The programs net and lm, which can be called under
$xLMX/bin
The script lmx for starting and stopping the server (with the NetBIOS administration
program) and the server status display.
Important changes to the previous version for Version 2.0 and later:
The domain concept is supported.
You can route the output of the printer spooler to a printer that is connected to a client
(shared client printer).
The share table and usernames are saved in a different format (if required this data can
be converted manually for the new version).
The MS-DOS notation must be used with the command net, for example options may
only be introduced with the character “/”.
For shared directories, c: must always be specified with the command net share,
e.g. net share sf1=c:/u1/sf1.
Programs which create LM named pipes must have root authorization.
LAN Manager/X must be started when creating the LM named pipes.
Remote systems can be administered from a client with the command net admin. For
this purpose, the server name must always be specified e.g.
net admin \\server1 /command
The prefix net must always be set in the administration shell.
The configuration file is now called
$xLMX/lanman.ini, and only contains values which
deviate from standard. The program
srvconfig should always be used for viewing or
modification functions. The chapter “Lanman.ini File“ contains a description of this.