Bedienungsanleitung

s
en
Operating Instructions
Radio module WZU-RF, WZU-RF-EXT
From firmware version 4.69
A6V12318600_----_a
2021-01-28
Translation
Comply with ESD protection measures.
Avoid short-circuits on the PCB.
Route connecting cables through the cable grommets
of the meter only.
Do not cut the grommets shorter than necessary
since this may lower the degree of protection.
Changes in the data telegram or the transmission
rate affect the battery life.
The meter sends no data telegram after delivery ex-
factory. The transmission starts after the installation
of the meter.
The module must not be plugged in during test-
ing / calibrating a meter on a test bench! For mount-
ing or removing the module, the 6-pole connector
shall be used for handling only!
Note: For meter of the type T550 (UH50…) firmware
5.23, new functions are available (C1 mode, OMS
4.1.2 with security profile B).
Number
Description
1
Service button (under the housing cover)
2
Slot “module 1
3
Slot “module 2
4
Bushing for power cable
5
Cable grommets
Note: You will find the permitted module combina-
tions in the respective Technical Description. The
radio functions depend on the T550 firmware.
Note: The module WZU-RF and WZU-RF-EXT may
be fitted at slot module 2 only.
Note: Open the cable grommets in such a way that
they enclose the cable tightly.
Note: When retrofitting a meter with radio module, the
voltage supply must be checked and, if necessary,
replaced. A battery type D or a power supply is re-