Operating Instructions

© 2020, Elvaco AB. All rights reserved. The documentation and product are provided on an “as is” basis only and may contain deciencies or in-
adequacies. Elvaco AB takes no responsibility for damages, liabilities or other losses by using this product. No part of the contents of this manual
may be transmitted or reproduced in any form by any means without the written permission of Elvaco AB. Printed in Sweden.
CMi6110 Quick manual A4 English
Version: 1.0
CONTACT INFORMATION
Elvaco AB Technical support:
Phone: +46 300 434300
E-mail: support@elvaco.com
Online: www.elvaco.com
Product Item number
CMi6110, incl. magnet mount antenna 1100338
CMi6110, incl. PSU (230V) and magnet
mount antenna
1100339
SAFETY
The warranty does not cover damage to the product caused by usage in
any other way than described in this manual. Elvaco AB can not be liable
for personal injury or property damage caused by usage in any other way
than described in this manual.
ORDERING INFORMATION  ELVACO
After you have set all conguration parameters, push Apply and place
the phone on the right side of the meter (next to the CMi6110 device).
Hold the phone still until it vibrates. This conrms that new settings have
successfully been transferred to the device via NFC.
NOTE
Make sure to locate the NFC antenna on your phone. When you
scan or write new congurations to the module, you should place
the phone’s NFC antenna as close as possible to the NFC antenna
of the module (4).
TECHNICAL SPECIFICATIONS
Mechanics
Protection class IP54 (in meter)
Dimensions (w x h x d) 85 x 36 x 20 mm
Weight 15 g
Mounting In Landis+Gyr UH50/UC50 module
slot 2
Antenna External via pigtail with SMA-f
connector. Antenna is ordered
separately
SIM card Slide, mini size
Electrical connections
Power supply WZU-AC 110/230-xx PSU or WZU-
ACDC24-50
Electrical characteristics
Nominal voltage 3.0-4.2 VDC
Power consumption (max) 200 mA
Power consumption (sleep
mode)
10 µA
Environmental specications
Operating temperature 5 °C to 55 °C
Operating humidity 0 - 93 % RH, no condensation
Operating altitude 2000 m
Pollution degree Degree 1
Usage environment Indoors
Storage temperature -20 °C to 60 °C
Mobile network
Transmit power Maximum 23.0 dBm
Receiver sensivity -1 35 dBm
Band 8, 20
3GPP Release 13 (NB1)
User interface
Green LED Status
Red LED Error
Push button Start-up / reboot
Conguration NFC via Elvaco OTC App or
remotely via DM system
Approvals
EMC EN 301489-1, EN 301 489-52
ORDERING INFORMATION  Landis + Gyr
Product Item number
NB-IoT module without antenna and
PSU
WZU-NB-IoT-EXT