Operating Instructions

© 2020, Elvaco AB. All rights reserved. The documentation and product are provided on an “as is” basis only and may contain deficiencies or in-
adequacies. Elvaco AB takes no responsibility for damages, liabilities or other losses by using this product. No part of the contents of this manual
may be transmitted or reproduced in any form by any means without the written permission of Elvaco AB. Printed in Sweden.
CMi4110 Quick Manual English
Version: 2.0
CONTACT INFORMATION
Elvaco AB Technical support:
Phone: +46 300 434300
E-mail: support@elvaco.com
Online: www.elvaco.com
SAFETY
The warranty does not cover damage to the product caused by usage in
any other way than described in this manual. Elvaco AB can not be liable
for personal injury or property damage caused by usage in any other way
than described in this manual.
SERVER CONFIGURATION
Before CMi4110 is able to transmit messages via the LoRaWAN network,
device information needs to be added to the network server. More
specifically, the following parameters needs to be registered (in OTAA
mode) in order to enable the network server to receive messages from
the module:
Device EUI (16-digit number printed on the device label)
Application key
Join EUI
NOTE
If activation mode is set to “ABP”. the application key does not need to
be added to the network server. Instead, the following information will
be needed: Network session key, Application session key and Device
address.
TECHNICAL SPECIFICATIONS
Mechanics
Dimensions 80 x 38 x 23 mm
Weight 35 g
Mounting In module slot 2 of Landis+Gyr
UH50 / UC50
External antenna connector SMA female
Electrical connections
Supply voltage Internal meter battery (D cell) or
PSU (Elvaco: CMip2110 230V,
Landis+Gyr WZU-AC230-xx or
WZU-ACDC24-00)
Electrical characteristics
Nominal voltage 3.0 VDC
Power consumption (max) 40 mA
Power consumption (sleep mode) ~2.2 µA
Environmental specifications
Operating temperature +5 °C to +55 °C
Operating humidity 0 - 93 % RH, no condensation
Operating altitude 2000 m
Usage environment Indoors
Storage temperature -20 °C to +60 °C
Radio characteristics
Frequency 868 MHz
Output power 14 dBm
Receiver sensitivity -135 dBm
LoRaWAN characteristics
Device class Class A, Bi-directional
LoRaWAN version 1.0
Activation OTAA or ABP
Data rate DR0-DR5 (250 bit/s-5470 bit/s)
User Interface
Green LED Start-up / reboot / switch-off
indicator
Red LED Start-up / reboot / switch-off
indicator
Push Button Start-up / reboot / switch-off
Configuration NFC via Elvaco OTC app or
downlink data
Approvals
EMC EN 301 489-1, EN 301 489-3