Technical data
CAUTION: For devices with explosion protection the maximum permitted voltages and currents according to the
EC-Type-Examination Certificate have to be observed.
Digital error
Resistance thermometer
Resistance-based sensors
Thermocouples
1)
Accuracy data refer to the largest error in the complete measuring range
Voltage/current sources
Input Measuring range Max. permissi-
ble line resis-
tance
Digital error
°C / (°F) : °C / (°F)
IEC 751
•Pt10
-200 ... +850
(-328 ... +1562)
20 3.0 (5.4)
•Pt50
-200 ... +850
(-328 ... +1562)
50 0.6 (1.1)
•Pt100
-200 ... +850
(-328 ... +1562)
100 0.3 (0.5)
•Pt200
-200 ... +850
(-328 ... +1562)
100 0.6 (1.1)
•Pt500
-200 ... +850
(-328 ... +1562)
100 1.0 (1.8)
•Pt1000
-200 ... +850
(-328 ... +1562)
100 1.0 (1.8)
JIS C 1604-81
•Pt10
-200 ... +649
(-328 ... +1200)
20 3.0 (5.4)
•Pt50
-200 ... +649
(-328 ... +1200)
50 0.6 (1.1)
•Pt100
-200 ... +649
(-328 ... +1200)
100 0.3 (0.5)
DIN 43760
•Ni50
-60 ... +250
(-76 ... +482)
50 0.3 (0.5)
•Ni100
-60 ... +250
(-76 ... +482)
100 0.3 (0.5)
•Ni120
-60 ... +250
(-76 ... +482)
100 0.3 (0.5)
•Ni1000
-60 ... +250
(-76 ... +482)
100 0.3 (0.5)
Input Measuring
range
Max. permissi-
ble line resis-
tance
Digital error
: : :
Resistance
(linear)
0...24 5 0.08
0...47 15 0.06
0...94 30 0.06
0...188 50 0.08
0...375 100 0.1
0...750 100 0.2
0 ... 1500 75 1.0
0 ... 3000 100 1.0
0 ... 6000 100 2.0
Input Measuring range Digital error
1)
°C / (°F) °C (°F)
Type B
0 ... +1820
(+32 ... +3308)
3 (5.4)
Type C
0 ... +2300
(+32 ... +4172)
2 (3.6)
Type D
0 ... +2300
(+32 ... +4172)
1 (1.8)
Type E
-200 ... +1000
(-328 ... +1832)
1 (1.8)
Type J
-210 ... +1200
(-346 ... +2192)
1 (1.8)
Type K
-200 ... +1372
(-328 ... +2501)
1 (1.8)
Type L
-200 ... +900
(-328 ... +1652)
2 (3.6)
Type N
-200 ... +1300
(-328 ... +2372)
1 (1.8)
Type R
-50 ... +1760
(-58 ... +3200)
2 (3.6)
Type S
-50 ... +1760
(-58 ... +3200)
2 (3.6)
Type T
-200 ... +400
(-328 ... +752)
1 (1.8)
Type U
-200 ... +600
(-328 ... +1112)
2 (3.6)
Input Measuring range Digital error
mV sources (linear) mV PV
-1 ... +16 35
-3 ... +32 20
-7 ... +65 20
-15 ... +131 50
-31 ... +262 100
-63 ... +525 200
-120 ... +1000 300
V sources (linear) V mV
-1.2 ... +10 3
-12 ... +100 30
-120 ... +140 300
PA/mA sources
(linear)
PA/mA PA
-12 ... +100 PA 0.05
-120 ... +1000 PA 0.5
-1.2 ... +10 mA 5
-12 ... + 100 mA 50
-120 ... +1000 mA 500