User's Manual

TC12 Installation, Commissioning & Maintenance Handbook
figuration (KMS) L
2 }{ sensor: 1 - 23 }= Input line number: {0 - 31} (255)
T in tate(s) for the
a ding
on the phase type being monitored (see table below).
The following is a list of the lamp mains state entries required for the different
s can monitor. If no mains state is required
55.
3.3.3.37 Mains states input con
KMS {mains state input: 0-
his item def es the digital inputs that provide the mains s
ssociated current sensor. Up to three input line numbers are required depen
pha e types that the current sensors
enter the default value of 2
Monitored Phase Type 1st entry 2nd entry 3rd entry
IV GREEN - -
IVRLM GREEN RED -
IP GREEN VEH. GREEN -
PV GREEN PED. GREEN -
PP GREEN - -
PPW GREEN WAIT -
PS VEH. GREEN PED. GREEN WAIT
IP GREEN VEH. GRW EEN WAIT
IPS VEH. GREEN PED. GREEN WAIT
XP1 RED - -
XV1 GREEN - -
XV2 BALL - -
XV3 GREEN AMBER -
W4 WAIT - -
W WAIT 6 - -
RS - - -
SB SIGN - -
ST SIGN - -
In addition, for PB392 Firmware:
PP4 GREEN WAIT -
PS4 VEH GREEN PED GREEN WAIT
IP4 PED GREEN VEH GREEN WAIT
IS4 VEH GREEN PED GREEN WAIT
Note The 32
the as
comm
inputs are numbered 1 to 32 in section 3.2.3.5, corresponding to
sociated pin on the 40 way input connector, however the handset
and numbers the inputs from 0 to 31, for the 32 inputs.
666/HE/43100/000 Page 106 Issue 9