TC65 Release Notes
Strictly Confidential / Released
s
TC65_rn_v01.041 Page 5 of 8 17.10.2005
2 General Hardware and Software Limitations
Noise Reduction and Echo Cancellation are working only at low quality level. Basic
Handsfree operation (Speakerphone) is not yet supported. The Ringing Tone generator
does not always work reliably.
The feature RTC wake-up from POWER DOWN mode is not available. Programming an
alarm time (AT+CALA) will not wake up the module automatically. Despite this, AT+CALA
can be used any time during normal operation.
Autobauding does not work reliably. It is recommended to set a fixed bit rate. By default,
when shipped from factory or after a firmware update, the modules are set to
115200 bps.
3 Hardware Limitations Specific to the TC65 Terminal
This section applies only to the TC65 Terminal.
After switching the TC65 Terminal off by using the EMERGOFF signal wait at least 1 second
(from the deactivation of EMERGOFF) before restarting the TC65 Terminal. During this
1 second period, invalid states may occur on the GPIO connector and on the serial interface.
4 Software Limitations
When changing from data to command mode, the TC65 fails to indicate the correct
response and, instead, returns a response related to the last event. The error occurs with
CSD connections, connections set up by using the Internet Service AT commands of
TC65 and the operation of I
2
C and SPI.
For example, after the remote party has closed the CSD connection, the TC65 returns
the response “CONNECT 9600/RLP” instead of “NO CARRIER”.
The maximum number of concurrent IP sockets is 8, due to memory limitations. This
includes all socket connections, no matter whether established from the Java application
or by using the Internet Service AT commands of TC65.
Please consider that the Java classes SocketConnection, Http(s)Connection,
SecureConnection and UDPDatagramConnection use up one socket each. The amount
of sockets for each ServerSocketConnection is two sockets for queued connection
requests and one socket reserved to accept the next connection. Each further accepted
connection occupies one socket.
The Socket Listener may not work properly if the service is re-opened shortly after having
closed the Socket Listener. To ensure that the service works correctly the host is
required to wait at least two minutes before re-opening a Listener.
The handling of the Master Phone Code (PH-SIM PUK) currently differs from the
description provided in [1]. This release of TC65 requires both the Master Phone Code
and the new “PS” password be given at the same time. So, at present, the TC65 will