Specifications

AT Command Set
TC3X_ATC_01_V04.00 Page 40 of 204 29.05.2002
2.45 AT+ILRR Set TE-TA local rate reporting
Test command
AT+ILRR=?
Response
+ILRR: (list of supported <value>s) OK
Parameter
See write command
Read command
AT+ILRR?
Response
+ILRR: <value> OK
Parameter
See write command
Write command
AT+ILRR=
<value>
The write command specifies whether or not an intermediate result code shall
indicate the currently used local rate when an incoming or outgoing data call is
established. The message is transmitted from the DCE (= TA) to the DTE (=TE)
before the final result code of the connection setup (e.g. CONNECT) appears.
Response
OK
Parameter
<value> 0 Disables reporting of local port rate
1 Enables reporting of local port rate
Intermediate result code
+ILLR:<rate>
Parameter
<rate> port rate setting in bit per second
0 (Autobauding, see Chapter 2.46.1)
300
600
1200
2400
4800
9600
14400
19200
28800
38400
57600
115200
Reference
V.25ter
Note
Example
ATD030112233445
+ILRR: 57600
CONNECT 9600/RLP