Specifications
AT Command Set
TC3X_ATC_01_V04.00 Page 177 of 204 29.05.2002
See notes above or contact provider.
if <fac> = “SC” then PIN
if <fac> = “AO”...”AC” (barring) then network password
if <fac> = “P2” then PIN2
<newpwd> new password
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>
Reference
Siemens
Note
See also specification of AT+ CPWD in GSM 07.07 and further details in Chapter
4.34.
6.37 AT^SSCONF SMS Configuration
Test command
AT^SSCONF
=?
Response
^SSCONF: (list of supported <ra>s)
Parameter
See write command
Read command
AT^SSCONF?
Response
^SSCONF: <ra> OK
Parameter
See write command
Write command
AT^SSCONF=
<ra>
The write command serves to control the presentation of the recipient address
parameters <ra> and <tora>.
Response
OK
Parameter
<ra>: display recipient address
0 the mobile station shall not display the parameter <ra> and <tora>.
1 the mobile station shall display the parameter <ra> and <tora>.
Please note that the setting is stored volatile, i.e. after restart or reset, the default
value 0 will be restored. Also, there is no way to store AT^SSCONF to the user
defined profile.
Reference
Siemens
Note
The parameters <ra> and <tora> appear in the result codes of the AT commands
AT+CMGL, AT^SMGL, AT+CMGR, AT^SMGR and the unsolicited result code
+CDS.