Specifications

AT Command Set
TC35-ATC-01-V02.10 Page 33/145 02.10 / 23.05.2001
previous bit rate.
b) Because in autobaud mode the ME doesn´t know which bit rate is to be
used after power-on. For this reason the unsolicited result code
“SYSSTART” cannot be sent. Therefore it is recommended to first send
an At Command string (see pg. 10) to the ME to let the autobaud
mechanism determine the bit rate used by the TE.
5. If this command switches from a bit rate that can´t be detected by the
autobaud mechanism (e.g. 300 baud) to autobaud mode (via +IPR=0), the
responses of +IPR=0 and all following commands on the same line may be
corrupted.
6. If autobauding is active, the command A/ (and a/) can not be used.
7. If autobauding is active, the multiplex mode (see +CMUX, pg. 67) can not be
activated.
8. If multiplex mode has been entered, +IPR=<rate> is not possible.