Specifications
AT Command Set
TC35-ATC-01-V02.10 Page 21/145 02.10 / 23.05.2001
2.17 ATQ Set result code presentation mode
Write command
ATQ[<n>]
Response
This parameter setting determines whether or not the TA transmits any result
code to the TE. Information text transmitted in response is not affected by this
setting.
If <n>=0:
OK
If <n>=1:
(none)
Parameter
<n> 0 DCE transmits result code
1 Result codes are suppressed and not transmitted
Reference
V.25ter
Note
2.18 ATP Select pulse dialling
Execute command
ATP
Response
OK
Reference
V.25ter
Note
No effect for GSM
2.19 ATS0 Set number of rings before automatically answering the call
Read command
ATS0?
Response
<n>OK
Write command
ATS0=<n>
This parameter setting determines the number of rings before automatic
answering.
Response
OK
Parameter
<n> 000 automatic answering is disabled
001-255 enable automatic answering on the specified ring
number
Reference
V.25ter
Note
• This command works only in data and fax mode.
• The TC35 supports the registers S0 - S29. A user can change
S0,S3,S4,S5,S6,S7,S8,S10 and S18 via the related ATSn commands.
The other registers are read-only and for internal usage only!