Specifications

AT Command Set
TC35-ATC-01-V02.10 Page 126/145 02.10 / 23.05.2001
6.24 AT^SNFV Set loudspeaker volume
Test command
AT^SNFV=?
Response
^SNFV: (list of supported <outStep>s) OK
Parameter
See write command
Read command
AT^SNFV?
Response
^SNFV: <outStep>
OK
Parameter
See write command
Write command
AT^SNFV=<ou
tStep>
Response
TA sets the volume of the loudspeaker to the value <outCalibrate> addressed by
<outStep>.
OK
Parameter
<outStep> Volume range 0 to 4
Reference
Siemens
Note
1. Read and write commands are related to the active audio mode.
2. The changes are allowed in audio modes 2 to 6.
3. <outStep> can be changed by AT^SNFO, too.
4. <outCalibrate> can be changed by AT^SNFO.
5. The changed <outStep> value will not be saved via AT^SNFW but via
AT^SMSO during „switch off“.
6.25 AT^SNFW Write audio setting in non-volatile store
Test command
AT^SNFW=?
Response
OK
Execute command
AT^SNFW
Response
TA writes the active audio parameters in non-volatile store related to the active
mode.
OK
If error is related to ME functionality:
+ CME ERROR: <error>
<error> memory failure Flash write error
Reference
Siemens
Note
Execute command works only in audio mode 2 to 6.
TA writes the following audio parameter values in non-volatile store:
<inBbcGain>, <inCalibrate>, <outBbcGain>, <outCalibrate[0]> ... <outCalibrate[4]>,
<side Tone>