Specifications

AT Command Set
TC35-ATC-01-V02.10 Page 12/145 02.10 / 23.05.2001
2.3 AT\Qn Flowcontrol
Execute command
AT\Q<n>
Response
OK
Parameter
<n> 0 AT\Q0 disables flow control
1 AT\Q1 XON/XOFF software flow control
2 AT\Q2 only CTS by DCE
3 AT\Q3 RTS/CTS
Reference
Note
Line state refers to RS-232 levels.
2.4 ATA Answer a call
Execute command
ATA
Response
TA causes remote station to go off-hook (e.g. answer call).
Note1: Any additional commands on the same command line are ignored.
Note2: This command may be aborted generally by receiving a character during
execution. It can“t be aborted in some connection setup states, such as
handshaking.
If successfully connected:
Response in case of data call:
CONNECT<text>
Note: <text> output only if +ATX parameter setting with value > 0.
TA switches to data mode.
Response in case of voice call:
OK
When TA returns to command mode after call release:
OK
If no connection
NO CARRIER
Parameter
Reference
V.25ter
Note
See also AT+ATX and chapter 7.4 for <text>