Specifications
TC35i AT Command Set
Confidential / Released
TC35i_ATC_V01.05 Page 90 of 278 04.08.2003
4.11.1 Wake up the ME from SLEEP mode
A wake-up event is any event that switches off the SLEEP mode and causes the ME to return to full
functionality. In short, it takes the ME back to AT+CFUN=1.
Definitions of the state transitions described in Table 12:
Yes = ME exits SLEEP mode.
No = ME does not exit SLEEP mode.
Table 12: Wake-up events in NON-CYCLIC and CYCLIC SLEEP modes
Event From SLEEP mode
AT+CFUN=0 to
AT+CFUN=1
From SLEEP mode
AT+CFUN=5 or 6 to
AT+CFUN=1
From SLEEP mode
AT+CFUN=7 or 8 to
AT+CFUN=1
Ignition line No No No
Activation of /RTS0 Yes No No
Unsolicited Result Code
(URC)
Yes Yes No
Incoming voice or data call Yes Yes No
Any AT command
(incl. outgoing voice or data
call, outgoing SMS)
Not possible
(UART disabled)
No No
Incoming SMS depending on
mode selected by AT+CNMI:
AT+CNMI=0,0 (= default, no
indication of received SMS)
AT+CNMI=1,1 (= displays
URC upon receipt of SMS)
No
Yes
No
Yes
No
No
RTC alarm Yes Yes No
AT+CFUN=1 Not possible
(UART disabled)
Yes Yes
Recommendation:
ยท In NON-CYCLIC SLEEP mode, you can set an RTC alarm to wake up the ME and return to full
functionality. This is a useful approach because, in this mode, the AT interface is not accessible.