Specifications

TC35i AT Command Set
Confidential / Released
TC35i_ATC_V01.05 Page 86 of 278 04.08.2003
Example 2
User attempts to set up a multiparty call, though there are only two parties in-
volved in the present conversation:
Atd”017511223344”;
OK
at+chld=2
OK
at+chld=3
+CME ERROR: operation temporary not allowed
at+ceer
+CEER: 22,0,2 Location ID stated in Chapter 8.1.5: 22 = SIEMENS
cause for L3 call related SS. The reference points
to Chapter 8.1.14 where 2 = “Initial conditions not
fulfilled” (one active, one held call). 0 = “No error
(parameter <reason> is not applicable).
Example 3
User attempts to activate call barring. Activation is denied by the network since
the password is blocked after previous failures to enter the password.
at+clck=”oi”,1,”0000”,3
+CME ERROR: incorrect password
at+ceer
+CEER: 35,0,43 Location ID stated in Chapter 8.1.5: 35 = Supple-
mentary Services network error. The reference
points to Chapter 8.1.13 where 43 = “Num-
berOfPWAttemptsViolation” (for example if wrong
password has been entered 3 times or more). 0 =
“No error” (parameter <reason> is not applicable).