Specifications
TC35i AT Command Set
Confidential / Released
TC35i_ATC_V01.05 Page 35 of 278 04.08.2003
2.28 ATS18 Extended error report
Read command
ATS18?
Response
<n> OK
Write command
ATS18=<n>
The write command enables or disables the presentation of more detailed error
messages reported in the case of unsuccessful CSD or fax calls.
Parameter of the write command
<n> 0 – 255
Odd numbers enable the presentation of extended error reports.
Even numbers disable the presentation of extended error reports.
Response
OK
Extended error report
If the presentation is enabled (odd number), the TA returns an extended error re-
port every time it fails to establish a data or fax call. Errors are reported only for
failures that occur before call setup is complete, for example if the result code
NO CARRIER, NO DIALTONE or BUSY appears.
Extended error report
+CAUSE: <location ID>: <reason >
Parameters of the extended error report
<location ID> Location ID as number code
Location IDs are listed in Chapter 8.1.5. Each ID is related to an-
other table that contains a list of <reason>s.
<reason> Reason for last failure, stated as number code
<reason> numbers and associated descriptions are listed in sev-
eral tables, sorted by different categories (see Chapters 8.1.6 to
8.1.18). The Chapter numbers can be found proceeding from the
Location ID table in Chapter 8.1.5.
Reference
Siemens
Note
This command applies only to circuit switched data calls and fax calls. For voice
calls, extended error reports can be retrieved using the execute command
AT+CEER (Chapter 4.10).
Example
To enable the presentation of extended error reports:
ats18=1
OK
Now, a mobile originated data call fails. Call setup is terminated with an extended
error report, followed by the result code NO CARRIER:
atd0301234567
+CAUSE: 8:16
NO CARRIER
The Location ID 8 stated in Chapter 8.1.5 points to Chapter 8.1.11, where 16 =
“Normal call clearing”.