Specifications
TC35i AT Command Set
Confidential / Released
TC35i_ATC_V01.05 Page 242 of 278 04.08.2003
Before first using ringing tones:
We have chosen to let you decide your own preferences when you start using
ringing tones. Therefore, factory setting is AT^SRTC: 3,0,3,0,0 (ringing tones
are muted). To activate ringing tones for the very first time, first enter the
Write command and simply change the volume.
<type>=0:
AT^SRTC=0 can be entered to quickly mute the ringing tone or melody cur-
rently played to indicate an <event>. No settings will be changed or saved.
<type>=0 immediately stops the audible ringing tone, but does not terminate
the URC (for example RING).
Execute Command
AT^SRTC
The Execute command is intended for testing. It starts to play a melody from
the audio output currently selected with the AT^SNFS command.
Response
OK
To stop the test use AT^SRTC again. During test playback, you can enter the
Write command to select another melody and adjust the volume. Also, you
can enter the Read command to check the type and volume of the current
ringing tone, and to view the status of playback (on / off).
The test ringing signal cannot be activated when an MTC is ringing (ERROR).
If an MTC arrives during test playback, test ringing stops and “normal“ ringing
is activated (RING).
Selecting <vol>=0 during the test, immediately stops playback. After this, ring-
ing tones will be muted until you change <vol> using the Write command.
Reference
SIEMENS