7.41 AT^SPLW Write an entry to the preferred operators list
Test command
AT^SPLW=?
Response
TA returns the whole index range supported by the SIM.
^SPLW: (list of supported <index>s) OK
If error is related to ME functionality:
+CME ERROR: <err>
Parameter
See write command
Write command
AT^SPLW=
<index>
[,<oper>]
Parameter
TA writes an entry to the SIM list of preferred operators at location number <in-
dex>. If <index> is given but <oper> is left out, the entry is deleted.
<index> location number
<oper> string type; operator in numeric form (= GSM location area identification
number) Consists of a three digit country code followed by a two or three
digit network code (see GSM 04.08 section 10.5.1.3).
Response
OK
If error is related to ME functionality:
+CME ERROR: <err>
Reference
Siemens
Note
See also GSM 07.07: AT+CPOL