Specifications

TC35i AT Command Set
Confidential / Released
TC35i_ATC_V01.05 Page 233 of 278 04.08.2003
^SPBS: 3,"+49177222222",145,"Esther"
^SPBS: 4,"0304444444",129,"Gilbert"
OK
Example 2
If the last record in the sorted list has been reached, then the internal counter
overflows to the first index:
at^spbs=1
^SPBS: 33,"+49301234567",145,"Tom Tailor"
^SPBS: 1,"01799999999",129,"Charly"
^SPBS: 2,"+49175555555",145,"Dave"
OK
Example 3
After resetting the internal counter to zero (using AT&F), AT^SPBS=2 takes you
to the <maxindex> of AT^SPBG and overflows to the first index.
at&f Reset internal counter to 0.
OK
at^spbs=2
^SPBS: 33,"+49301234567",145,"Tom Tailor"
^SPBS: 1,"01799999999",129,"Charly"
^SPBS: 2,"+49175555555",145,"Dave"
OK