2.3 AT\Qn Flow control
Execute command
AT\Q<n>
Response
OK
If RTS/CTS flow control is not supported by interface and <n> is 2 or 3
ERROR
Parameter
<n> 0 AT\Q0 No flow control
1 AT\Q1 XON/XOFF software flow control
2 AT\Q2 Only CTS by DCE
3 AT\Q3 RTS/CTS hardware flow control
Recommended for the following procedures: in-
coming or outgoing data calls, fax calls, MUX
mode.
Often, the initialization routine of Fax programs in-
cludes enabling RTS/CTS handshake, eliminating
the need to issue AT\Q3 once again.
Reference
Note
· Factory default is 0 (no flow control). The setting of AT\Qn is stored volatile.
For use after restart it should be stored to the user defined profile (AT&W).
· When using XON/XOFF flow control ( AT\Q 1) in online mode, +++ should not
be used while the data transmission is paused with XOFF. Before entering the
command mode with +++ the paused transmission should be resumed using
the XON character.
· For compatibility reasons, the AT\Qn command can be used in Multiplex mode,
though the settings will not take effect. However, be aware that whenever you
use the AT\Qn write command in Multiplex mode and then save the current
configuration to the user profile with AT&W, the changed AT\Qn setting will be-
come active after restart.
· Flow control can also be set using AT+IFC. See Chapter 2.45.