Example 2
Attempt to manually select a forbidden operator:
AT+COPS=1,2,26203
OK
If the selected operator was not allowed, the ME is now unregistered. The
read command will return only the mode, but no operator:
AT+COPS?
+COPS: 1
In this case, the test command returns only that the desired operator is avail-
able (<stat=1). Nevertheless, the registration is not successful. Please use the
AT+CREG command (Chapter 4.41) to verify the registration status.
AT+COPS=?
+COPS: (1,"D2",,"26202"),(3,"E-Plus",,"26203"),(3,"T-
D1",,"26201"),(3,"Interkom",,"26207"),,(0-4),(0,2)
OK
AT+CREG?
+CREG: 0,3 (where 3 = registration denied)