Specifications

TC35i AT Command Set
Confidential / Released
TC35i_ATC_V01.05 Page 103 of 278 04.08.2003
<passwd> password. For each <fac> a different type of password is required.
See Chapters 4.38 and 7.42 for instructions of how to specify pass-
words.
<class> integer or sum of integers each representing a <class> of information:
1 voice
2 data
4 fax
8 short message service
16 data circuit sync
32 data circuit async
64 dedicated packet access
128 dedicated PAD access
x combination of some of the above classes.
For example, the default setting 7 represents the sum of the
integers 1, 2 and 4 (call barring for voice, data and fax). The
value 255 covers all classes. If the <class> parameter is
omitted, the default value 7 is used.
See examples in 4.21.3 for correct handling of class numbers.
<class> 2 (data) comprises all those <class> values between 16 and
128, that are supported both by the network and the MS. This means,
a setting made for <class> 2 applies to all remaining data classes (if
supported). In addition, you can assign a different setting to a specific
class. For example, you can activate call barring for all data classes,
but deactivate it for a specific data class.
<status> 0 off
1 on
Reference
GSM 07.07
GSM 02.04
GSM 02.88
GSM 03.88
GSM 04.88
Note
· If an outgoing international voice call is rejected due to active call barring
supplementary service, the call will be terminated with result code NO
DIALTONE.
Under the same conditions, an outgoing fax or data call will be terminated
with result code NO CARRIER.
· The command has been implemented with the full set of <class> parameters
according to GSM 07.07. For actual applicability of a specific <fac> to a
specific service or service group (a specific <class> value) please consult
table A.1 of GSM 02.04.
· AT^SLCK is a Siemens defined command equivalent to AT+CLCK. See
Chapter 7.15.