User Manual
en
Operating Instructions
Pulse output module T450
27.02.2020
Pulse output module T450 Subject to change without prior notice 3
1. Safety Information
Please observe the technical data of the pulse out-
put..
Ensure ESD protection.
Avoid short-circuits on the PCB.
Always route connecting cables through the grom-
mets of the meter.
Do not cut the grommets shorter than necessary
since this may lower the degree of protection.
Only ever touch the module on its plastic holder.
The meter has no lightning protection. Ensure light-
ning protection via the house installation.
2. Description of function
The pulse output module T45-PULSE enables the output of
pulses on 2 configurable channels.
On channel 1 (terminals 16, 17)
• energy (CE)
• volume (CV)
• tariff register 1 (C1)
pulses can be output.
On channel 2 (terminals 18, 19)
• volume (CV)
• tariff register 1 (C1)
• tariff register 2 (C2)
pulses can be output.
The pulse duration is identical on both channels.
3. LCD
Note: Depending on the device parameterization,
both the display scope and the displayed data may
deviate from this description.
LOOP 2 “LOOP 2”
Loop head
Pulse function
Pulse duration
Pulse value of pulses for
energy alternating with pulse
value of pulses for volume
Channel assignment of pulse
function
4. Parameterization
The pulse function is pre-parameterized with CE for channel 1
(CH1) and CV for channel 2 (CH2).
An adjustment can be made via UltraAssist.
Pulse value
Standard pulses are set to
• 100 ms pulse duration and
• 1 kWh / 1 MJ or 10 l.
High-definition pulses are set to
• 10 ms pulse duration and
• 0.1 kWh / 0.1 MJ or 1 l.
Settings for standard pulses
Pulse for energy, volume
Period duration > 200ms
Pulse duration 100 ms conducting
Settings for high definition pulses
Pulse for energy, volume
Period duration > 20 ms
Pulse duration 10 ms conducting
4.1 Installing the communication
Proceed as follows to install a communication module:
• If necessary, open the housing cover by loosening the
screw.
• Run the cable from the outside through the grommet.
• Strip and connect the cable.
• Secure the cable with the strain relief clamp.
• Connect the cables to the module’s terminals.
• Pull the cables out through the housing while inserting the
module.
• First attach the contact surfaces of the module to the mod-
ule slot.
• Gently push the module in.