User Manual
· Automatic exchange of heating and cooling
requests with the primary plant
· Manual/remote control of lighting
· Constant light control
· Manual/remote control of blinds
· Blind protection control
· Control of blinds according to a time schedule
· Facade shading control
· Sunlight tracking control
· Shadow outline tracking control for more daylight
· Central acquisition and monitoring of HVAC,
lighting and blind status and room occupancy
· Heating/cooling energy efficiency indication of
primary plant
· Remote alarming
Time- and presence-dependent temperature control saves
up to 20% heating / cooling energy.
Demand-controlled ventilation saves 20% (office rooms) to
70% (conference rooms) ventilation energy.
Time-, presence- and daylight-dependent lighting control
saves up to 45% lighting energy.
Time- and daylight-dependent shading control saves up to
30% heating / cooling energy.
Energy efficiency indicator saves energy by informing the
facility manager about energy waste and faults of the primary
plant.
* To reach energy performance class A, the automatic exchange
of heating and cooling requests with the primary plant is re-
quired.
7 High-end application
Energy performance class A
39
VAV with floor heating:
· Individual room temperature control according to
time program, presence detection and windows
status
· Demand dependent control of fresh air supply
· Automatic exchange of heating and cooling
requests with the primary plant
· Manual/remote control of lighting
· Automatic switching of lights according to the
presence status and brightness level in the room
· Constant light control
· Manual/remote control of blinds
· Blind protection control
· Control of blinds according to a time schedule
· Facade shading control
· Sunlight tracking control
· Shadow outline tracking control for more daylight
· Central acquisition and monitoring of HVAC,
lighting and blind status and room occupancy
· Heating/cooling energy efficiency indication
· Remote alarming
Individual room temperature control and automatic data
exchange with the primary plant saves up to 30% heating /
cooling energy.
Time- and presence-dependent temperature control saves
up to 20% heating / cooling energy.
Demand-controlled ventilation saves 20% (office rooms) to
70% (conference rooms) ventilation energy.
Time-, presence- and daylight-dependent lighting control
saves up to 45% lighting energy.
Time- and daylight-dependent shading control saves up to
30% heating / cooling energy.
Energy efficiency indicator saves energy by informing the
facility manager about energy waste and faults.