Network Hardware User Manual
U3585-J-Z125-8-76 381
Messages NPS0528
NPS0528 INVALID DEVICE DEFINITION SPECIFIED FOR DEVICE ’(&00)’
(B) Routing code: R Weight: 99
Meaning
When defining a monitoring program, an attempt was made to specify a device that is not
valid for this program.
The statement has been rejected.
Possible reasons:
- device is unknown
- device is not a disk
- device is not attached
- device is a GS volume
NPS0529 INVALID CHANNEL DEFINITION SPECIFIED FOR CHANNEL NUMBER ’(&00)’
(B) Routing code: R Weight: 99
Meaning
When defining a monitoring program, an attempt was made to specify an invalid channel
number.
The statement has been rejected.
NPS0530 MONITORING PROGRAM ’(&00)’ INVALID DEFINED. STATEMENT REJECTED
Meaning
It was attempted to start a monitoring program with invalid devices.
Invalid devices are:
- Devices, which are not any more in the configuration
- Devices, which are not in the status ’ATTACHED’ (only for measurement program DISK)
- GS-Volumes
Response
Check and correct monitoring program definition.
NPS0531 WARNING: MONITORING PROGRAM ’(&00)’ PARTLY INVALIDLY DEFINED. INVALID DEVICES
IGNORED
Meaning
While starting a monitoring program, it was found that some invalid devices were selected.
The monitoring program is only started with the valid devices; the invalid devices are not
monitored.
Invalid devices are:
- Devices, which are not any more in the configuration
- Devices, which are not in the status ’ATTACHED’ (only for measurement program DISK)
- GS-Volumes