User's Manual
2-12
1010NFM-3JSection 2
NOTE: The currently active table will be shown highlighted next to the [UniMass Table] menu
cell. If no table is active then [Disable] will appear highlighted next to the [UniMass
Table] menu cell.
NOTE: The [Changing Temp & Vs] lookup table must be serially loaded using the HyperTermi-
nal “Send Text” command. This table can be generated using a utility provided by
Controlotron, which converts the Vs and temperature data into a uniform 10x10 grid
array and formats it appropriately for serial download.
* Must recognize degrees C, degrees F selection.
** Vs, SG and Viscosity must be greater than 0.0. Enable permitted only after table contains at least
two entries of correctly formatted data.
*** Pipe Configuration Default.
APPLICATION DATA MENU STRUCTURE (continued)
Application Data Liquid Class Viscosity cS x.xx (numeric entry)
Density SG x.xxx (numeric entry)
UniMass Table Disabled
Constant Temp Create/Edit Table Table Point New
Vs xx.xxx
S.G. xx.xx
Viscosity (cS) x.xxx
Accept Yes
Clear Pt.
Clear Table No/Yes
Table Active Yes/No
Constant Vs Create/Edit Table Table Point New
Temperature xx.xxx *
S.G. x.xxx
Viscosity (cS) x.xxx
Accept Yes
Clear Pt.
Clear Table No/Yes
Table Active Yes/No
Changing Temp & Vs Table Active Yes/No **
Temp Range -40F to 250F
-40F to 375F
-40F to 450F
Pipe Config Fully Developed***
(Change to Up- 1 Elbow
stream Piping) Dbl Elbow +
Dbl Elbow -
Valve
Expander
Reducer
Norm Entry
Header Inlet
Intrusions
Anomaly Diams xxxx (numeric entry)