User's Manual

2-8
1010NFM-3JSection 2
2.2.1 HOW TO SELECT A PIPE CLASS
The 1010N pipe tables are arranged by classes of common type and material. The default selection is
[Manual Entry]. As its name infers, you would use this selection to manually enter individual pipe pa-
rameters.
To select a Pipe Class:
To access the [Pipe Class] option list press
To scroll through the available classes press
To select the class that fits your application press
When you pick a Pipe Class, the Select Pipe Size menu cell (see below) presents the pipe size option
list associated with the selected class. By using the pipe class and pipe size option lists, you automati-
cally load all the required pipe information. You can also select a pipe class/size, then edit any of the
associated defaults to fine-tune the pipe data.
NOTE: Create custom pipe data via the Pipe Table editor in the Meter Facilities menu.
2.2.2 HOW TO SELECT A PIPE SIZE
Selecting a Pipe Size installs the selected pipe parameters into the balance of the Pipe Data menu
cells and prepares the 1010 for Transducer selection and Installation. This option is not applicable if the
Pipe Class is [Manual Entry].
ENT
THE PIPE DATA MENU STRUCTURE (continued)
Pipe Data (cont.) Pipe Material Steel
ABS
Aluminum
Black Iron
Brass
Cast Iron
CuNi (70/50)
CuNi (90/10)
Copper
Ductile Iron
FRP
Glass
Hastelloy
Inconel
Nickel
Polyethylene
PVC (Plastic)
Silicone
Teflon
Titanium
Wall Thickness x.xxx (numeric entry)
Liner Material None
Cement
Coal Tar
Enamel
Glass
Plastic
HDPE
Teflon
Rubber
Liner Thickness x.xxx (numeric entry)